7.8.9. D
ISASSEMBLING THE WEIGHT STACK PULLEY
Figure 7.8.9-1
Follow the steps described in paragraph 7.8.7.
“Disassembling the rear plexiglas weight stack
guard”.
1. Unscrew the screw
a
and the nut
b
using 2
17-gauge wrenches.
2. Remove the PULLEY.
To replace the PULLEY, follow the above steps
in reverse order.
For easier disassembly and reassembly
of the PULLEY, it may be necessary to
loosen the cable tension.
When the operation is complete, adjust
the cable tension as described in
paragraph 8.4. .