BIOSTRENGTH LINE: Service & Maintenance manual - rev. 2.1
Page 7.15
7.1.13. D
ISASSEMBLING THE ZERO SENSOR
Figure 7.1.13-1
Follow the steps described in paragraph 7.1.6.
“Disassembling the plexiglas weight stack
guard” limited solely to the internal part.
1. Loosen the counter-nut
a
using a 13-gauge
wrench.
2. Disconnect the connector
b
from the cable.
3. Remove the ZERO SENSOR.
To reassemble the ZERO SENSOR, follow the
above steps in reverse order.
When the operation is complete, adjust
the position of the SENSOR as described
in paragraph 8.8. .