BIOSTRENGTH LINE: Service & Maintenance manual - rev. 2.1
Page 2.52
•
Solenoid interface board (labeled GF970405 - order code 0WQ080)
Name Type of connector
Connection
CN1
4-pin male AMP MODU II
Signals: CPU connection
CN2
2-pin female AMP MNL
Solenoid
CN3
2-pin terminal board
18 Vac 1A power supply
•
Weight stack motor interface board (labeled GF970305 - order code 0WQ119)
Name Type of connector
Connection
CN1
6-pin male AMP MODU II
Signals: CPU connection
CN2
2-pin terminal board
18 Vac 5A power supply
CN3
6-pin female AMP MNL
24 Vdc motor with reed
•
Seat motor interface board (labeled GF991206 - order code 0WQ00011)
Name Type of connector
Connection
CN1
6-pin male AMP MODU II
Signals: CPU connection
CN2
2-pin terminal board
18 Vac 5A power supply
CN3
6-pin female AMP MNL
24 Vdc motor with reed
CS1
2-pin open male AMP MINIFIT
Safety sensor input signal
CS2
2-pin male AMP MODU II
Reset
•
FPGA Board (labeled GF970601 - order code 0WQ069)
Name Type of connector
Connection
CN1
8-pin male AMP MODU II
Signals: connection with encoder
CN2
6-pin male AMP MODU II
RS-232 serial to CPU
CN3
4-pin male AMP MODU I
Low voltage: +12 Vdc, +5 Vdc, ground
CN4
4-pin male AMP MODU I
Low voltage: +12 Vdc, +5 Vdc, ground
•
Patch cords
Name Type of connector
Connection
CN21 6-pin open male AMP MNLI
Weight stack motor and reed power
supply
CN23 6-pin open male AMP MODU II
Encoder signals
CN24 2-pin open male AMP MODU II
Zero sensor signal
CN25 2-pin open male AMP MODU II
Zero sensor signal
CN26 4-pin open male AMP MODU II
Solenoid power supply
CN27 4-pin open male AMP MODU II
Solenoid power supply
CN28 2-pin open female AMP MINIFIT
Safety sensor signal
CN29 2-pin open male AMP MINIFIT
Safety sensor signal
Summary of Contents for BIOSTRENGTH LINE
Page 1: ...SERVICE MAINTENANCE MANUAL REV 2 1...
Page 2: ......
Page 4: ......
Page 16: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page xii Page intentionally left blank...
Page 88: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 2 70 Page intentionally left blank...
Page 99: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 3 11 Figure 3 2 5...
Page 122: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 4 2 Page intentionally left blank...
Page 634: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 9 26 Page intentionally left blank...
Page 645: ......