7.5.34. D
ISASSEMBLING THE CROSS AND WEIGHT STACK PLATES
Figure 7.5.34-1
Follow the steps described in paragraph 7.5.30.
“Disassembling the columns” limited solely to
the right-hand column.
1. Select the minimum weight (5 Kg or 10 lbs.).
For each bar:
2. Loosen the dowel
a
using a 4-gauge
hexagonal T-wrench.
3. Remove the counter-weight.
4. Disconnect the solenoid cable connector.
5. Unhook the encoder cable.
Figure 7.5.34-2
6. Raise the CROSS until the cross sinker is
released from the WEIGHT STACK
PLATES, and lock in this position.
Follow the steps described in paragraph 7.5.33.
“Disassembling the bars”.
7. Remove the CROSS and WEIGHT STACK
PLATES by sliding them out from the side.
Make sure the stack of PLATES does
not tip over.
To reassemble the CROSS and WEIGHT
STACK PLATES, follow the above steps in
reverse order.
Summary of Contents for BIOSTRENGTH LINE
Page 1: ...SERVICE MAINTENANCE MANUAL REV 2 1...
Page 2: ......
Page 4: ......
Page 16: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page xii Page intentionally left blank...
Page 88: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 2 70 Page intentionally left blank...
Page 99: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 3 11 Figure 3 2 5...
Page 122: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 4 2 Page intentionally left blank...
Page 634: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 9 26 Page intentionally left blank...
Page 645: ......