S
E
A
T P
R O B
L
E
M =
F A I L
To exit this error condition, carry out the checks described in paragraph 6.13. “The LCD
displays the message “Seat problem = fail””.
This error does NOT prevent the machine from being used, but produces a beep,
displaying the message on the LCD for 5 seconds, then allows you to use the machine
but without moving the seat.
2. Motor – encoder problem
If, during movement, the CPU board receives no encoder signal for approximately 60 seconds,
this means there is no movement due to a probable motor fault, or that there is movement but it
is not detected by a defective encoder. In this case, the machine displays the following message
on the LCD:
S
E
A
T P
R O B
L
E
M =
G E N E R I C
To exit this error condition, shut off the machine, switch it back on and see which error appears
on the LCD display. Carry out the checks described in paragraphs 6.15. “The LCD displays the
message “Seat problem = motor”” and 6.16. “The LCD displays the message “Seat problem =
encoder””.
This error does NOT prevent the machine from being used, but produces a beep,
displaying the message on the LCD for 5 seconds, then allows you to use the machine
but without moving the seat.
This test procedure does not allow you to detect problems on the TGS interface,
FPGA or zero sensor. In addition, the checks carried out are less sensitive than those
performed during the reset procedure. Thus whenever the machine shows an error
message during operation, we recommend that you shut it off, switch it back on and
check the error messages displayed by the reset procedure as described in paragraph
6.3. .
Summary of Contents for BIOSTRENGTH LINE
Page 1: ...SERVICE MAINTENANCE MANUAL REV 2 1...
Page 2: ......
Page 4: ......
Page 16: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page xii Page intentionally left blank...
Page 88: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 2 70 Page intentionally left blank...
Page 99: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 3 11 Figure 3 2 5...
Page 122: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 4 2 Page intentionally left blank...
Page 634: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 9 26 Page intentionally left blank...
Page 645: ......