BIOSTRENGTH LINE: Service & Maintenance manual - rev. 2.1
Page 6.18
YES
Check whether the machine works
if the TLCBR is replaced with a
functional one
NO
Replace the CPU board
Check whether the BS-TLCBR
cable is intact
5
YES
Replace the BS-TLCBR
cable
NO
A
Replace the TLCBR
Follow the step-by-step guide to properly diagnose the error. Pay special attention to those tests
indicated in numbered boxes, and described in detail here below:
(1)
Disconnect the flat cable connector from the key reader. Insert the tester probes between pins
4 and 7 (ground) on the same connector. The table below shows the numbering in a flat cable
connector:
1 3 5 7 9
2 4 6 8 10
You should get a reading of approximately 12 Vdc.
(2)
Disconnect the flat cable connector from the TLCBR. Insert the tester probes between pins 4
and 7 (ground) on the same connector. You should get a reading of approximately 12 Vdc.
(3)
Disconnect the AMP MODU II 8-pin connector from TLCBR. Insert the tester probes
between pins 1 and 3 (ground) on the same connector. You should get a reading of
approximately 12 Vdc.
(4)
Disconnect the K6 connector from the CPU board. Insert the tester probes between pins 1 and
2 (ground) on the same connector. You should get a reading of approximately 12 Vdc.
(5)
Check the continuity of the cable wires, following the diagram in paragraphs 2.6. and 2.5. .
Summary of Contents for BIOSTRENGTH LINE
Page 1: ...SERVICE MAINTENANCE MANUAL REV 2 1...
Page 2: ......
Page 4: ......
Page 16: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page xii Page intentionally left blank...
Page 88: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 2 70 Page intentionally left blank...
Page 99: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 3 11 Figure 3 2 5...
Page 122: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 4 2 Page intentionally left blank...
Page 634: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 9 26 Page intentionally left blank...
Page 645: ......