BIOSTRENGTH LINE: Service & Maintenance manual - rev. 2.1
Page 8.2
The setting of the OFFSET parameter, which may be configured as described in paragraph 9.2.2.
“Offset zero sensor”, must be adjusted in order to correctly select the first plate: the selection brush
must be positioned so as to press against the plate pin, touching it with the beginning of the flat part
as shown in the figure below:
Figure 8.1.1-1
Once you have set the OFFSET parameter, note its value on the sticker inside the display (old
version equipment) or beneath the Plexiglas cover (new version equipment) so that it may be rapidly
configured in case the data stored in the battery-powered RAM are lost, or if the electronic boards of
the display are replaced.
The OFFSET value generally needs to be changed after any operations requiring
dismantling the weight stack selection system or after the machine has been in use for
some time.
8.1.2. D
ISTANCE BETWEEN PLATES
After setting the offset parameter, we recommend increasing the weight in increments of 5 Kg (10
lbs) to check whether the selection is perfect, plate by plate. In this case the lower plate pin must be
pressed as shown in the figure above, and the upper plate pin released and at least a couple of mm
from the brush, as shown in the figure below:
Figure 8.1.2-1
Summary of Contents for BIOSTRENGTH LINE
Page 1: ...SERVICE MAINTENANCE MANUAL REV 2 1...
Page 2: ......
Page 4: ......
Page 16: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page xii Page intentionally left blank...
Page 88: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 2 70 Page intentionally left blank...
Page 99: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 3 11 Figure 3 2 5...
Page 122: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 4 2 Page intentionally left blank...
Page 634: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 9 26 Page intentionally left blank...
Page 645: ......