BIOSTRENGTH LINE: Service & Maintenance manual - rev. 2.1
Page 7.373
7.9.27. D
ISASSEMBLING THE ELECTRONIC COMPONENTS OF THE MAIN ELECTRICAL
BOX
Figure 7.9.27-1
Follow the steps described in paragraph 7.9.26.
“Disassembling the main electrical box”.
With the electrical box resting on a bench:
To disassemble the POWER SUPPLY
a
:
1. Disconnect the 2 connectors.
2. Disconnect the 4 plastic coupling elements.
3. Remove the card.
To disassemble the FPGA BOARD
b
:
1. Disconnect the 4 connectors.
2. Disconnect the 4 plastic coupling elements.
3. Remove the card.
To disassemble the IMP BOARD
c
:
1. Lift the board.
2. Disconnect the 2 connectors.
3. Disconnect the 4 plastic coupling elements.
4. Remove the card.
To disassemble the IEM BOARD
d
:
1. Lift the board.
2. Disconnect the 2 connectors.
3. Disconnect the 4 plastic coupling elements.
4. Remove the card.
To disassemble the TRANSFORMER
e
:
1. Disconnect the secondary cables from the
board connectors.
2. Unsolder the primary cables from the selector
switch.
3. Unscrew the holding screw a using an 8-
gauge wrench.
4. Remove the transformer.
Continued on next page
→
Summary of Contents for BIOSTRENGTH LINE
Page 1: ...SERVICE MAINTENANCE MANUAL REV 2 1...
Page 2: ......
Page 4: ......
Page 16: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page xii Page intentionally left blank...
Page 88: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 2 70 Page intentionally left blank...
Page 99: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 3 11 Figure 3 2 5...
Page 122: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 4 2 Page intentionally left blank...
Page 634: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 9 26 Page intentionally left blank...
Page 645: ......