7.5.32. D
ISASSEMBLING THE ENCODER
Figure 7.5.32-1
Follow the steps described in paragraph 7.5.30.
“Disassembling the columns” limited solely to
the right-hand column.
1. Release the slot
a
of the ENCODER wire
from the hook.
Figure 7.5.32-2
2. Disconnect the connector
b
of the
ENCODER cable.
3. Cut the clamp
c
.
4. Disconnect the connector
d
from the encoder
cable.
5. Unscrew the 3 screws
e
using a 3-gauge
hexagonal T-wrench.
6. Remove the ENCODER.
Hold the ENCODER up before
unscrewing the last screw.
To replace the ENCODER, follow the above
steps in reverse order.