7.1.19. D
ISASSEMBLING THE SINKER
Figure 7.1.19-1
Follow the steps described in paragraph 7.1.18.
“Disassembling the cross”.
1. Place the cross on a bench or flat surface.
2. Unscrew the 2 screws
a
using an 8-gauge
hexagonal T-wrench.
3. Remove the cable connector flange
b
.
4. Use a 30-gauge Allen wrench to unscrew the
ring-nut
c
.
5. Remove the SINKER.
To reassemble the SINKER, follow the above
steps in reverse order.