BIOSTRENGTH LINE: Service & Maintenance manual - rev. 2.1
Page 9.1
9. CONFIGURING THE MACHINE
9.1. CONFIGURING PARAMETER DEFAULTS
Proceed as follows:
1. Shut the machine off.
2. Open the display and set all dip-switches to OFF.
3. Switch the machine on.
4. The machine turns on and loads the default parameters as though it were an Abdominal.
To change the configuration, you may use the procedure described in paragraphs 9.2. “Configuring
the technical parameters” and 9.3. “Configuring the user parameters”.
CAUTION: if the dip-switches are all OFF when the machine is turned on, the
configuration parameter value is read by the EPROM (default configuration), otherwise
it is read by the battery RAM (custom configuration). Thus in order to save changes to
the parameters, before shutting off the machine dip-switch 1 must be set to On.
9.2. CONFIGURING THE TECHNICAL PARAMETERS
Technical parameters are those that may be changed only by an authorized technician, since they
have to do with configuring the construction parameters of the equipment.
The procedure for configuring technical parameters may be activated, when the machine is in stand-
by, by pressing keys “1”, “3” and “4” simultaneously, and making sure that the dip-switches on the
CPU Board are set to configuration 1000. To access this procedure, you must enter the password
that protects against unauthorized access.
P A S S W O R D =
*
After entering the password “2501” and pressing “Enter” to continue, the machine begins to offer
the configurable parameters in sequence, showing the current value and possible alternatives. Press
the "Enter" key to move on to the next parameter, or the “Clear” key to quit the procedure.
Pressing the “Clear” key will abort the procedure, but any changes previously made will
remain in effect. However, you must reset or turn the machine off and back on again in
order for the changes to affect the current program session.
Summary of Contents for BIOSTRENGTH LINE
Page 1: ...SERVICE MAINTENANCE MANUAL REV 2 1...
Page 2: ......
Page 4: ......
Page 16: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page xii Page intentionally left blank...
Page 88: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 2 70 Page intentionally left blank...
Page 99: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 3 11 Figure 3 2 5...
Page 122: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 4 2 Page intentionally left blank...
Page 634: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 9 26 Page intentionally left blank...
Page 645: ......