BIOSTRENGTH LINE: Service & Maintenance manual - rev. 2.1
Page 9.11
9.3. CONFIGURING THE USER PARAMETERS
Before carrying out this procedure, make sure that the type of machine is correctly set
as described in paragraph 9.2. “Configuring the technical parameters”.
User parameters are those that may be changed directly by the user, since they have to do with
configuring the use and interface of the equipment.
The procedure for configuring user parameters may be activated, when the machine is in stand-by,
by pressing keys “1”, “3” and “4” simultaneously, and making sure that the dip-switches on the
CPU Board are set to Position 1000. To access this procedure, you must enter the password that
protects against unauthorized access.
P A S S W O R D =
*
After entering the password “2406” and pressing “Enter” to continue, the machine begins to offer
the configurable parameters in sequence, showing the current value and possible alternatives. Press
the "Enter" key to move on to the next parameter, or the “Clear” key to quit the procedure.
Pressing the “Clear” key will abort the procedure, but any changes previously made will
remain in effect. However, you must reset or turn the machine off and back on again in
order for the changes to affect the current program session.
9.3.1. L
ANGUAGE
This option allows you to set the program language:
L A N G U A G E I = 1 U S A = 2
U K = 3 D = 4 F = 5 N L = 6 X
The following options are available:
•
Italian = 1;
•
American English = 2;
•
British English = 3;
•
German = 4;
•
French = 5;
•
Dutch = 6.
Select the desired option, then press “Enter” to continue or “Clear” to abort.
9.3.2. U
NIT OF MEASURE
This option allows you to set the unit of measure for weights used by the system:
S E L E C T M E A S U R E U N I T
K G = 1 L B S = 2 X
Summary of Contents for BIOSTRENGTH LINE
Page 1: ...SERVICE MAINTENANCE MANUAL REV 2 1...
Page 2: ......
Page 4: ......
Page 16: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page xii Page intentionally left blank...
Page 88: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 2 70 Page intentionally left blank...
Page 99: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 3 11 Figure 3 2 5...
Page 122: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 4 2 Page intentionally left blank...
Page 634: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 9 26 Page intentionally left blank...
Page 645: ......