BIOSTRENGTH LINE: Service & Maintenance manual - rev. 2.1
Page 7.213
7.6.2. R
EMOVING THE ELECTRONIC DISPLAY BOARDS
Figure 7.6.2-1
Follow the steps described in paragraph 7.6.1.
“Disassembling the display”.
With the display resting on a bench:
To remove the CPU
a
and LED
b
BOARDS:
1. Disconnect the connector
c
from the
keyboard.
2. Disconnect the connector
d
from the
TLCBR.
3. Disconnect the connectors
e
from the LCD.
4. Use a small Philips screwdriver to unscrew
the 5 screws
f
.
5. Remove the CPU and LED BOARDS.
6. To separate the CPU and LED boards,
disconnect the 2 connectors and 4 coupling
elements.
When finished, configure the machine
parameters as described in paragraphs
9.2. and 9.3. .
To disassemble the TLCBR
g
:
1. Disconnect the 2 connectors
h
.
2. Use a medium-sized straight screwdriver to
unscrew the 3 holding screws
i
.
3. Remove the board.
To disassemble the KEY READER
l
:
1. Disconnect the connector
m
.
2. Use a medium-sized Philips screwdriver to
unscrew the 2 screws
n
.
3. Remove the connector block
o
.
4. Remove the KEY READER.
Continued on next page
→
Summary of Contents for BIOSTRENGTH LINE
Page 1: ...SERVICE MAINTENANCE MANUAL REV 2 1...
Page 2: ......
Page 4: ......
Page 16: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page xii Page intentionally left blank...
Page 88: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 2 70 Page intentionally left blank...
Page 99: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 3 11 Figure 3 2 5...
Page 122: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 4 2 Page intentionally left blank...
Page 634: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 9 26 Page intentionally left blank...
Page 645: ......