BIOSTRENGTH LINE: Service & Maintenance manual - rev. 2.1
Page 3.32
•
Reset signal
This is the signal generated by the CPU (pin 6 on connector K3 - pin 1 on connector K4) each
time the power supply is switched on to reset the top plate position. This signal enters the Bio
servo board (pins 18-1 on connector CN7).
The control logic states that when the reset signal is normally high (~ 5 V), while at the power
on the signal goes low (~ 0 V) for about 100
µ
sec e and then it goes back to high.