BIOSTRENGTH LINE: Service & Maintenance manual - rev. 2.1
Page 7.311
Figure 7.8.10-3
4. Using 2 22-gauge wrenches, loosen the
counter-nut
d
then unscrew the screw
e
from
the cable terminal until the cable is free.
5. Disconnect the connector
f
from the solenoid
cable.
6. Remove the spiral cable
g
and its guide
h
from the hook
i
.
Figure 7.8.10-4
7. Use a 6-gauge hexagonal T-wrench to
unscrew the 8 screws
l
.
8. Pull the WEIGHT STACK COVER upward
and rest it on the seat, being careful not to
damage the cable.
To reassemble the WEIGHT STACK COVER,
follow the above steps in reverse order.
When the operation is complete, adjust
the cable tension as described in
paragraph 8.4. .