Bio Servo board (labeled GF981005 - order code 0WQ121)
Name Type of connector
Connection
CN1
6-pin male AMP MINIFIT
24 Vdc weight stack motor with reed
CN2
6-pin male AMP MINIFIT
24 Vdc seat adjustment motor with reed
CN3
6-pin male AMP MODU II
Encoder and Solenoid
CN4
2-pin male AMP MINIFIT
Zero sensor signal
CN7
18-pin male AMP MODU II
Signals: CPU connection
CN8
4-pin male AMP MODU I
Low voltage: +12 Vdc, +5 Vdc, ground
CN9
4-pin male AMP MODU I
Low voltage: +12 Vdc, +5 Vdc, ground
CN10 2-pin terminal board
18 Vac 10A power supply
CE1
2-pin male AMP MODU II
Signals: safety device input
•
Sensor interface board (labeled GF991031 - order code 0WQ00007)
Name Type of connector
Connection
CN1
2-pin open male AMP MINIFIT
Safety sensor input signal
CN2
4-pin male AMP MODU II
Safety sensor input signal to driver board
CN3
2-pin male AMP MODU II
Reset
•
Patch cords
Name Type of connector
Connection
CN21 6-pin open male AMP MINIFIT
Weight stack motor and reed power
supply
CN23 6-pin open male AMP MODU II
Encoder signals
CN24 4-pin open male AMP MODU II
Solenoid power supply
CN25 4-pin open female AMP MODU II
Solenoid power supply
CN26 4-pin open male AMP MODU II
Solenoid power supply
CN27 2-pin open male AMP MODU II
Zero sensor signal
CN28 2-pin open female AMP MINIFIT
Safety sensor signal
CN29 2-pin open male AMP MINIFIT
Safety sensor signal
2.5.3.2. Cables
BS-11: High-voltage power cable
Power socket – Power switch – Earth node
Power socket
CN11
Signal
Color
Power switch
CN13
PE
Faston Earth
Yellow–green -
Slot
Faston Neutral
Black
Faston
-
Faston Phase
Black
Faston
-
Summary of Contents for BIOSTRENGTH LINE
Page 1: ...SERVICE MAINTENANCE MANUAL REV 2 1...
Page 2: ......
Page 4: ......
Page 16: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page xii Page intentionally left blank...
Page 88: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 2 70 Page intentionally left blank...
Page 99: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 3 11 Figure 3 2 5...
Page 122: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 4 2 Page intentionally left blank...
Page 634: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 9 26 Page intentionally left blank...
Page 645: ......