![background image](http://html1.mh-extra.com/html/omron/sysmac-nx1p2-10-1-series/sysmac-nx1p2-10-1-series_user-manual_1633435271.webp)
Additional Information
Unit Addresses
Unit addresses are used to identify each of devices connected to a single node on a network.
Unit addresses are set as shown below.
• CPU Unit: 00 hex
NJ-series CPU Unit
As shown in the table below, the network type number and the destination address are determined
depending on whether the output is routed (1) to a Unit on the CPU Rack or (2) from a communica-
tions port on a Communications Unit.
Route
Network type number (hexadec-
imal)
Destination address (hexadeci-
mal)
(1) Output to a Unit on the CPU
Rack
#01 (backplane port)
Unit address of the destination
Unit (Refer to Additional Informa-
tion below.)
(2) Output from a communications
port on a Communications Unit
#02 (built-in EtherNet/IP port)
IP address
(2)
(1)
IP address
U
nit
address
Communications
port (#02)
Backplane
port #01
NJ-series CPU Unit
1. When Routing the Output to a Unit on the CPU Rack
Route the output to the backplane port for the network with the CPU Rack, with the Unit ad-
dress of the destination Unit specified as the destination address.
2. When Routing the Output from a Communications Port on a Communications Unit
Route the output to an EtherNet/IP port, with the IP address specified as the destination node
address.
Additional Information
Unit Addresses
Unit addresses are used to identify each of devices connected to a single node on a network.
Unit addresses are set as shown below.
• CPU Unit: 00 hex, 01 hex
• CPU Bus Units (EtherNet/IP Units): Unit 10 hex
8 CIP Message Communications
8-9
NJ/NX-series CPU Unit Built-in EtherNet/IP Port User’s Manual (W506)
8-2 CIP Message Communications Client Function
8
8-2-4
Route Path
Summary of Contents for Sysmac NX1P2-10 1 Series
Page 8: ...Manual Structure 6 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Page 34: ...Revision History 32 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Page 388: ...9 Socket Service 9 34 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Page 430: ...12 FTP Client 12 14 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Page 569: ...I Index I 1 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506 I...
Page 576: ...Index I 8 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Page 577: ......