![background image](http://html1.mh-extra.com/html/omron/sysmac-nx1p2-10-1-series/sysmac-nx1p2-10-1-series_user-manual_1633435353.webp)
The following data format is used if a specification is made in the Num of Element field for a
BOOL array. (Refer to
8-4-5 Specifying Variable Names in Request Paths
mation on the Num of Element field.) The status (TRUE/FALSE) is given in order for each ele-
ment of the BOOL variable.
Data Format
USINT
Data Type
C1 hex
USINT
00 hex
UINT
Num of Elem
(L)
Gives the number of elements in the array.
(H)
USINT
Status
01 hex: TRUE, 00 hex: FALSE
:
:
USINT
Status
Structure Variables
• Accessing an Entire Structure
If a structure variable is specified, it is treated as an access request for all of the members of the
structure.
Data Format
USINT
Data Type
A0 hex (Abbreviated STRUCT)
USINT
02 hex
UINT
CRC
(L)
CRC value for the structure definition
(H)
UINT
Num of Elem
(L)
01 hex
(H)
00 hex
:
Data
:
8 CIP Message Communications
8-91
NJ/NX-series CPU Unit Built-in EtherNet/IP Port User’s Manual (W506)
8-7
V
ariable Data T
ypes
8
8-7-4
Derived Data T
ypes
Summary of Contents for Sysmac NX1P2-10 1 Series
Page 8: ...Manual Structure 6 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Page 34: ...Revision History 32 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Page 388: ...9 Socket Service 9 34 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Page 430: ...12 FTP Client 12 14 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Page 569: ...I Index I 1 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506 I...
Page 576: ...Index I 8 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Page 577: ......