3
In the
Unregister Device List
, click the target device that requires connection settings so its
color changes to gray, and click the
Button.
The selected target device is displayed in the
Register Device List
, as shown below.
4
Target node IDs are assigned to the devices that are registered in the
Register Device List
.
The target node ID serves as the bit array position for the following variables in the originator
Controller: Target Node Controller Mode, Target Node Controller Error Information, Target
Node Error Information, Registered Target Node Information, and Normal Target Node
7 Tag Data Link Functions
7-37
NJ/NX-series CPU Unit Built-in EtherNet/IP Port User’s Manual (W506)
7-2 Setting T
ag Data Links
7
7-2-5
Connection Settings