A-8 Example of NX Unit Setting Using NX
Configuration Object Service
You can change the NX Unit settings by using the NX Configuration object service.
This section provides examples of the procedure for NX Unit setting using the NX Configuration object
service.
Refer to
8-5-3 NX Configuration Object (Class ID: 74 hex)
on page 8-50 for details on the NX Configu-
ration object.
The following three types of procedure are given as the examples.
• Changing the Unit operation settings for a singe NX Unit.
• Changing the Unit operation settings for multiple NX Units.
• Initializing the Unit operation settings for a singe NX Unit.
Precautions for Correct Use
Refer to
16-2 Checking Status with the Network Configurator
on page 16-3 for troubleshooting
errors that may occur while setting NX Units using the NX Configuration object service.
Version Information
You can perform the NX Unit setting using the NX Configuration object service only with NX102
CPU Units.
A-8-1
Changing the Unit Operation Settings for Singe NX Unit
Change the Unit operation settings for a single NX Unit mounted to the Controller. In this example, the
unit number of the NX Unit is 1.
The following table gives the setting procedure.
Step
Description
CIP Object to use
Class ID
Instance ID
Service code
Unit
number
1
Change the parameter write
mode of the NX Unit to Write
mode.
0x74
NX Configuration
object
0x01
0x37
Switch parameter
write mode
0x01
2
Write values to the NX object
of the NX Unit.
0x74
NX Configuration
object
0x01
0x34
Write NX object
0x01
3
Save the values that are set in
the NX Unit.
0x74
NX Configuration
object
0x01
0x36
Save parameter
0x01
4
Restart the NX Unit.
0x74
NX Configuration
object
0x01
0x35
Restart NX unit
0x01
Appendices
A-62
NJ/NX-series CPU Unit Built-in EtherNet/IP Port User’s Manual (W506)
Summary of Contents for Sysmac NX1P2-10 1 Series
Page 8: ...Manual Structure 6 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Page 34: ...Revision History 32 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Page 388: ...9 Socket Service 9 34 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Page 430: ...12 FTP Client 12 14 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Page 569: ...I Index I 1 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506 I...
Page 576: ...Index I 8 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Page 577: ......