Variable name
Meaning
Function
Data type
Range of
values
Reference
_EIP_TargetNo-
deErr[255]
Target Node Error In-
formation
NX-series CPU Units: Indicates that the
connection for the Registered Target
Node Information for CIP communica-
tions 1 was not established or that an er-
ror occurred in the target Controller.
The array elements are valid only when
the Registered Target Node Information
is TRUE.
Array[x] is TRUE:
A connection was not normally establish-
ed with the target node for a target node
ID of x (the Registered Target Node Infor-
mation is TRUE and the Normal Target
Node Information is FALSE), or a con-
nection was established with the target
node but an error occurred in the target
Controller.
Array[x] is FALSE:
The target node is not registered for a
target node ID of x (the Registered Target
Node Information is FALSE), or a con-
nection was normally established with the
target node (the Registered Target Node
Information is TRUE and the Normal Tar-
get Node Information is TRUE). An error
occurred in the target Controller (the Tar-
get PLC Error Information is TRUE).
NJ-series CPU Units: Indicates that the
connection for the Registered Target
Node Information was not established or
that an error occurred in the target Con-
troller.
The array elements are valid only when
the Registered Target Node Information
is TRUE.
Array[x] is TRUE:
A connection was not normally establish-
ed with the target node for a target node
ID of x (the Registered Target Node Infor-
mation is TRUE and the Normal Target
Node Information is FALSE), or a con-
nection was established with the target
node but an error occurred in the target
Controller.
Array[x] is FALSE:
The target node is not registered for a
target node ID of x (the Registered Target
Node Information is FALSE), or a con-
nection was normally established with the
target node (the Registered Target Node
Information is TRUE and the Normal Tar-
get Node Information is TRUE). An error
occurred in the target Controller (the Tar-
get PLC Error Information is TRUE).
ARRAY
[0..255] OF
BOOL
TRUE or
FALSE
3 System-defined Variables Related to the Built-in EtherNet/IP Port
3-30
NJ/NX-series CPU Unit Built-in EtherNet/IP Port User’s Manual (W506)
Summary of Contents for Sysmac NX1P2-10 1 Series
Page 8: ...Manual Structure 6 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Page 34: ...Revision History 32 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Page 388: ...9 Socket Service 9 34 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Page 430: ...12 FTP Client 12 14 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Page 569: ...I Index I 1 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506 I...
Page 576: ...Index I 8 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Page 577: ......