5-56
5-16 User Parameters
5
Ope
rati
ng Func
tions
Explanation of Settings
Explanation of Settings
• Use this parameter to assign the function of General-purpose Output 2 (OUTM2: CN1 pin 40).
Pn08
IM Selection
Setting range
0 to 12
Unit
---
Default setting
0
Power OFF
→
ON
---
Setting
Explanation
0
Torque command: 3 V/rated (100%) torque
1
Position deviation: 3 V/31 pulses
2
Position deviation: 3 V/125 pulses
3
Position deviation: 3 V/500 pulses
4
Position deviation: 3 V/2000 pulses
5
Position deviation: 3 V/8000 pulses
6
Reserved
7
Reserved
8
Reserved
9
Reserved
10
Reserved
11
Torque command: 3 V/200% torque
12
Torque command: 3 V/400% torque
Pn09
General-purpose Output 2 Selection
Setting range
0 to 8
Unit
---
Default setting
0
Power OFF
→
ON
---
Setting
Explanation
0
Output during torque limit
1
Zero speed detection output
2
Warning output for over regeneration, overload, absolute encoder battery, or fan lock
3
Over regeneration warning output
4
Overload warning output
5
Absolute encoder battery warning output
6
Fan lock warning output
7
Reserved
8
Speed conformity output
All modes
All modes
Summary of Contents for R88D-GT series
Page 20: ...18 Table of Contents ...
Page 234: ...3 133 3 8 Reactor Specifications 3 Specifications ...
Page 448: ...7 37 7 5 Manual Tuning 7 Adjustment Functions ...
Page 474: ...8 25 8 5 Periodic Maintenance 8 Troubleshooting ...
Page 475: ...Chapter 9 Appendix 9 1 Connection Examples 9 1 9 2 Parameter Tables 9 11 ...
Page 509: ......