6-4 Setting the Mode
6
Opera
tion
Automatic Offset Adjustment
1. Executing Automatic Offset Adjustment
Note
Do not perform this operation if a position loop has been configured with the host system.
2. Returning to Auxiliary Function Mode
Key operation
Display example
Explanation
Press the Data key to enter Automatic Offset Adjustment Mode.
Press and hold the Increment key until “Start” is displayed.
The bar indicator will increase when the key is pressed for 5 s or longer.
The bar indicator will increase.
Automatic offset adjustment will start.
This display indicates a normal completion.
“Error” will be displayed if the automatic offset adjustment could not be
performed. Set a valid control mode or make the setting so that the offset
value does not exceed the range for the Speed Command Offset
Adjustment (Pn52), and then perform the procedure again.
Key operation
Display example
Explanation
Press the Data key to return to Auxiliary Function Mode.
Automatic offset adjustment cannot be performed in Position Control
Mode.
Data is not written to the EEPROM simply by performing automatic offset
adjustment.
The data must be written to the EEPROM for the results to be saved.
okfksk k k-.k
okfksk k-k-.k
fknk_kokfksk
Precautions
for Correct Use
Summary of Contents for R88D-GT series
Page 20: ...18 Table of Contents ...
Page 234: ...3 133 3 8 Reactor Specifications 3 Specifications ...
Page 448: ...7 37 7 5 Manual Tuning 7 Adjustment Functions ...
Page 474: ...8 25 8 5 Periodic Maintenance 8 Troubleshooting ...
Page 475: ...Chapter 9 Appendix 9 1 Connection Examples 9 1 9 2 Parameter Tables 9 11 ...
Page 509: ......