![background image](http://html1.mh-extra.com/html/omron/r88d-gt-series/r88d-gt-series_user-manual_742798446.webp)
7-35
7-5 Manual Tuning
7
Adjustment Functions
Damping Control
When the machine end vibrates, damping removes the vibration frequency from the commands,
reducing vibration.
• Stop operation before changing the parameters or switching with DFSEL/PNSEL.
• Under the following conditions, damping control may not operate properly or may have no effect.
• The following conditions must be met to use damping control.
Conditions under which damping control operates
Control Mode
•
The Position Control Mode must be used.
Pn02 = 0: Position control
Pn02 = 3: Control mode 1 for position/speed control
Pn02 = 4: Control mode 1 for position/torque control
Conditions under which the effect of damping control is inhibited
Load
•
If forces other than commands, such as external forces, cause vibration.
•
If the ratio of the resonance frequency to anti-resonance frequency is large.
•
If the vibration frequency is outside the range of 10.0 to 200.0 Hz.
Encoder
Load
Servo-
motor
Servo Drive
Feedback pulse
Position
command
Torque
com-
mand Current
control
Position/
speed
control
Coupling
Servo Drive
Servomotor
Move-
ment
Moving body
Ball screw
Machine table
Set the frequency of the vibrating end.
Control
filter
Position controller
Vibrating end
Vibration measured
with Displacement Sensor
Precautions
for Correct Use
Summary of Contents for R88D-GT series
Page 20: ...18 Table of Contents ...
Page 234: ...3 133 3 8 Reactor Specifications 3 Specifications ...
Page 448: ...7 37 7 5 Manual Tuning 7 Adjustment Functions ...
Page 474: ...8 25 8 5 Periodic Maintenance 8 Troubleshooting ...
Page 475: ...Chapter 9 Appendix 9 1 Connection Examples 9 1 9 2 Parameter Tables 9 11 ...
Page 509: ......