9-14
9-2 Parameter Tables
9
Appe
ndix
09
General-
purpose Output
2 Selection
Assign the function of General-purpose Output 2
(OUTM2).
0
---
0 to 8
---
0
Output during torque limit
1
Zero speed detection output
2
Warning output for regeneration overload,
overload, absolute encoder battery, or fan
lock.
3
Regeneration overload warning output
4
Overload warning
5
Absolute encoder battery warning output
6
Fan lock warning output
7
Reserved
8
Speed conformity output
0A
General-
purpose Output
1 Selection
Assign the function of General-purpose Output 1
(OUTM1).
1
---
0 to 8
---
0
Output during torque limit
1
Zero speed detection output
2
Warning output for regeneration overload,
overload, absolute encoder battery, or fan
lock.
3
Regeneration overload warning output
4
Overload warning
5
Absolute encoder battery warning output
6
Fan lock warning output
7
Reserved
8
Speed conformity output
0B
Operation
Switch When
Using Absolute
Encoder
Set the operating method for the 17-bit absolute en-
coder.
0
---
0 to 2
Yes
0
Use as absolute encoder.
1
Use as incremental encoder.
2
Use as absolute encoder but ignore multi-turn
counter overflow.
0C
RS-232 Baud
Rate Setting
Select the baud rate for the RS-232 port.
2
---
0 to 5
Yes
0
2,400 bps
1
4,800 bps
2
9,600 bps
3
19,200 bps
4
38,400 bps
5
57,600 bps
Pn
No.
Parameter
name
Setting
Explanation
Default
setting
Unit
Setting
range
Power
OFF
→
ON
Summary of Contents for R88D-GT series
Page 20: ...18 Table of Contents ...
Page 234: ...3 133 3 8 Reactor Specifications 3 Specifications ...
Page 448: ...7 37 7 5 Manual Tuning 7 Adjustment Functions ...
Page 474: ...8 25 8 5 Periodic Maintenance 8 Troubleshooting ...
Page 475: ...Chapter 9 Appendix 9 1 Connection Examples 9 1 9 2 Parameter Tables 9 11 ...
Page 509: ......