5-70
5-16 User Parameters
5
Ope
rati
ng Func
tions
Torque Control Mode
• Use this parameter to select the conditions for switching between gain 1 and gain 2 when the Gain
Switching Input Operation Mode Selection (Pn30) is set to 1.
• The gain is always gain 1 regardless of the gain input if the Control Gain Switch 1 Setting (Pn31)
is 2 and the Torque Limit Selection (Pn03) is 3.
• If the Control Mode Setting (Pn02) is set to a composite mode (3, 4, or 5), the setting of this
parameter is valid when the first control mode is used.
*1. The Gain Switch 1 Time (Pn32) is used when returning from gain 2 to gain 1.
*2. The Gain Switch 1 Hysteresis Setting (Pn34) is defined as shown in the following figure.
*3. The amount of change is the value within 166
μ
s.
Example: When the condition is a 10% change in torque in 166
μ
s, the set value is 200.
*4. This is the encoder resolution.
*5. The meanings of the Gain Switch Time, Gain Switch Level Setting, and Gain Switch Hysteresis
Setting are different from normal if this parameter is set to 10. (Refer to Figure F.)
Setting
Explanation
Gain switching conditions
Gain Switch Time
(Pn32, 37)
*1
Gain Switch
Level Setting
(Pn33, 38)
Gain Switch
Hysteresis Set-
ting (Pn34, 39)
*2
0
Always gain 1 (Pn10 to Pn14)
×
×
×
1
Always gain 2 (Pn18 to Pn1C)
×
×
×
2
Switching using Gain Switch Input
(GSEL) for CN1 pin 27
×
×
×
3
Amount of change in torque command
(Figure A)
*3
(0.05%/166
μ
s)
*3
(0.05%/166
μ
s)
Pn33
0
Pn34
Pn32
Gain 1
Gain 2
Gain 1
Summary of Contents for R88D-GT series
Page 20: ...18 Table of Contents ...
Page 234: ...3 133 3 8 Reactor Specifications 3 Specifications ...
Page 448: ...7 37 7 5 Manual Tuning 7 Adjustment Functions ...
Page 474: ...8 25 8 5 Periodic Maintenance 8 Troubleshooting ...
Page 475: ...Chapter 9 Appendix 9 1 Connection Examples 9 1 9 2 Parameter Tables 9 11 ...
Page 509: ......