![background image](http://html1.mh-extra.com/html/omron/r88d-gt-series/r88d-gt-series_user-manual_742798391.webp)
6-10
6-4 Setting the Mode
6
Opera
tion
I/O Signal Status
• Displays the status of the control input and output signals connected to CN1.
Input Signals
CN1
Signal
No.
Abbreviation
Name
Pin
No.
00
RUN
RUN command
29
01
RESET
Alarm reset
31
02
NOT
Reverse drive prohibit
8
03
POT
Forward drive prohibit
9
04
TVSEL
Control mode switch
32
05
VZERO
Zero speed designation
26
06
GESEL
Electronic gear switch
28
08
IPG
Pulse disable
33
09
GSEL
Gain switch
27
0A
ECRST
Deviation counter reset
30
0C
VSEL1
Internally set speed selection 1
33
0D
VSEL2
Internally set speed selection 2
30
13
DFSEL
Vibration filter switch
26
14
VSEL3
Internally set speed selection 3
28
15
TLSEL
Torque limit switch
27
Input signal No. 00 ON
Output signal No. 1A OFF or disabled
ON
OFF or disabled
Signal No. display (0 to 1F hex)
Input
Output