6-4 Setting the Mode
6
Opera
tion
Warning Display
Regeneration Load Ratio
• Displays the regeneration resistance load ratio as a percentage of the detection level for the
regeneration load.
Overload Load Ratio
• Displays the load ratio as a percentage of the rated load.
Inertia Ratio
Total Feedback Pulses and Total Command Pulses
• Displays the total number of pulses after the power supply is turned ON.
• The display on the front panel will overflow as shown in the following figure.
• The display on the Parameter Unit will be as shown in the following figure.
• Use the Shift key to switch the display between the upper and lower digits of the total number of
pulses.
• Hold down the Data key for 5 s or longer to reset the total pulses to 0.
: No
w
arning,
: Warning
Overload: 85% or more of the alarm level for
overload.
Battery
w
arning: Absolute encoder battery voltage dropped to 3.2 V or less
Fan lock: Abnormal cooling fan speed.
Over-regeneration: 85% or more of the alarm level for regeneration
overload.
The alarm level
w
ill be 10% of the operating ratio of the regeneration
resistance if the Regeneration Resistor Selection (Pn6C) is set to 1.
Not used.
Displays the inertia ratio as a percentage.
2,147,483,647 pulses
−
2,147,483,647 pulses
−
2,147,483,647 pulses
Power ON
0
Forward
Reverse
Upper digits
Lower digits
Hk-k2k1kk4k7
4k8k3k6k4k7
Summary of Contents for R88D-GT series
Page 20: ...18 Table of Contents ...
Page 234: ...3 133 3 8 Reactor Specifications 3 Specifications ...
Page 448: ...7 37 7 5 Manual Tuning 7 Adjustment Functions ...
Page 474: ...8 25 8 5 Periodic Maintenance 8 Troubleshooting ...
Page 475: ...Chapter 9 Appendix 9 1 Connection Examples 9 1 9 2 Parameter Tables 9 11 ...
Page 509: ......