6-27
6-4 Setting the Mode
6
Opera
tion
4. Executing Copying
5. Returning to Copy Mode
Key operation
Display example
Explanation
Writing user parameters to the EEPROM of the Servo Drive will start.
This display indicates a normal completion.
Key operation
Display example
Explanation
Press the Data key to return to Copy Mode.
If “Error” is displayed before completion, repeat the procedure from the
beginning.
Press the Data key to clear the error.
If errors are repeatedly displayed, the following may be the cause: cable
disconnection, connector contact failure, incorrect operation due to noise,
or EEPROM fault in the Parameter Unit.
Do not disconnect the Parameter Unit from the Servo Drive while copying
is being performed. If the Parameter Unit is disconnected, incorrect data
may be written and the data may be corrupted. Copy the user parameters
again from the source Servo Drive to the Parameter Unit, and then copy
the user parameters from the Parameter Unit to the other Servo Drive.