4-43
4-3 Wiring Conforming to EMC Directives
4
System Design
Noise Filters for Servomotor Output
• Use noise filters without built-in capacitors on the Servomotor output lines.
• Select a noise filter with a rated current at least two times the Servo Drive's continuous output
current.
• The following table shows the noise filters that are recommended for Servomotor output.
Note 1.
Servomotor output lines cannot use the same noise filters for power supplies.
Note 2.
Typical general-purpose noise filters are made for power supply frequencies of 50/60 Hz. If
these noise filters are connected to the PWM output of the Servo Drive, a very large (about
100 times larger) leakage current will flow through the noise filter's condenser and the Servo
Drive could be damaged.
Dimensions
3G3AX-NF001/-NF002
Manufacturer
Model
Rated
current
Remarks
OMRON
3G3AX-NF001
6 A
For inverter output
3G3AX-NF002
12 A
3G3AX-NF003
25 A
3G3AX-NF004
50 A
3G3AX-NF005
75 A
3G3AX-NF006
100 A
Model
Dimensions (mm)
A
B
C
E
F
G
H
J
M
P
3G3AX-NF001
140
125
110
70
95
22
50
20
4.5 dia.
156
3G3AX-NF002
160
145
130
80
110
30
70
25
5.5 dia.
176
M4
C
B
A
P
E
F
J
H
G
Four, M
Summary of Contents for R88D-GT series
Page 20: ...18 Table of Contents ...
Page 234: ...3 133 3 8 Reactor Specifications 3 Specifications ...
Page 448: ...7 37 7 5 Manual Tuning 7 Adjustment Functions ...
Page 474: ...8 25 8 5 Periodic Maintenance 8 Troubleshooting ...
Page 475: ...Chapter 9 Appendix 9 1 Connection Examples 9 1 9 2 Parameter Tables 9 11 ...
Page 509: ......