3-102
3-5 Servo Relay Units and Cable Specifications
3
Specifications
Wiring
*1. If this signal is input, the output pulse from the CQM1 will be input to the high-speed counter.
*2. Input this output signal to a CQM1 Input Unit.
*3. The XB contacts are used to turn ON/OFF the electromagnetic brake.
*4. The phase-Z output is an open-collector output.
*5. Do not connect unused terminals.
*6. The 0 V terminal is internally connected to the common terminals.
*7. The following crimp terminal is applicable: R1.25-3 (round with open end).
0V
CW
CCW
RUN
INP
ALM
BKIR
10
0
19
9
CW
Z
RESET ALMCOM
FG
24 VDC
X1
XB
24 VDC
X1
ECRST
CCW
+24 V
Common Common
CQM1 Input Unit
(*2)
(*3)
(*1)
(*1)