1-11
1-5 Applicable Standards
1
Features and System Configuration
The Servo Drives and Servomotors comply with UL 508C (file No. E179149) as long as the following
installation conditions 1 and 2 are met.
(1)
Use the Servo Drive in a pollution degree 1 or 2 environment as defined in IEC 60664-1
(example: installation in an IP54 control panel).
(2)
Be sure to connect a circuit breaker or fuse, which is a UL-listed product with LISTED and
mark, between the power supply and noise filter.
Refer to the following table for the rated current of the circuit breaker or fuse.
Use copper wiring with a temperature rating of 60
°
C or higher.
Korean Radio Regulations (KC)
The G-series Servo Drives comply with the Korean Radio Regulations (KC).
The G-series Servomotors do not comply with the Korean Radio Regulations (KC).
SEMI F47
Some Servo Drives conform to the SEMI F47 standard for momentary power interruptions (voltage
sag immunity) for no-load or light-load operation.
This standard applies to semiconductor manufacturing equipment.
Note 1.
It does not apply to Servo Drivers with single-phase 100-V specifications or with
24-VDC specifications for the control power input.
Note 2.
Always perform evaluation testing for SEMI F47 compliance in the actual system.
Drive model
Circuit breaker (rated current) (A)
R88D-GTA5L
10
R88D-GT01L
10
R88D-GT02L
10
R88D-GT04L
10
R88D-GT01H
10
R88D-GT02H
10
R88D-GT04H
10
R88D-GT08H
15
R88D-GT10H
15
R88D-GT15H
20
R88D-GT20H
30
R88D-GT30H
50
R88D-GT50H
50
R88D-GT75H
60
Summary of Contents for R88D-GT series
Page 20: ...18 Table of Contents ...
Page 234: ...3 133 3 8 Reactor Specifications 3 Specifications ...
Page 448: ...7 37 7 5 Manual Tuning 7 Adjustment Functions ...
Page 474: ...8 25 8 5 Periodic Maintenance 8 Troubleshooting ...
Page 475: ...Chapter 9 Appendix 9 1 Connection Examples 9 1 9 2 Parameter Tables 9 11 ...
Page 509: ......