6-4
6-2 Preparing for Operation
6
Opera
tion
Displays on the Parameter Unit
• Connect the Parameter Unit to the Servo Drive and turn ON the power to the Servo Drive, or
alternatively, connect the Parameter Unit to the Servo Drive when power to the Servo Drive is
already ON. The following displays will appear.
1 s
8.8.8.8.8.8.
8.8.
8k8k8k8k8k8k
8k8kk
rk k k k k0k
. . . . . .
. .
Ukekrk1.0k0k
Ukekrk1.0k0k
Ukekrk1.0k0k
rk k k k k0k
k3.
k1
k1
k3.
k0.
· The Parameter Unit is initialized.
The display will flash every 0.6 s.
0.6 s
0.6 s
0.6 s
Servo Drive with unit number other than 0
Servo Drive with unit number 0
Communicating via RS-232 Only
Communicating with Other Drives
connected via RS-485
The microcomputer
version is displayed.
(The numbers depend on
the microcomputer
version.)
The Drive's unit number
set in parameter Pn00 is
displayed.
Default Display
(Determined
by the setting of
parameter Pn01.)
The Parameter Unit
version is displayed.
The dot will flash if RS-485 is
connected. Set the unit number
of the Drive to connect to using
the Increment and Decrement
keys.
The Parameter Unit
version is displayed.
The specified unit number
is displayed.
Press the Data key.
(0.6 s later)
Default Display
The specified unit number
is displayed.
Summary of Contents for R88D-GT series
Page 20: ...18 Table of Contents ...
Page 234: ...3 133 3 8 Reactor Specifications 3 Specifications ...
Page 448: ...7 37 7 5 Manual Tuning 7 Adjustment Functions ...
Page 474: ...8 25 8 5 Periodic Maintenance 8 Troubleshooting ...
Page 475: ...Chapter 9 Appendix 9 1 Connection Examples 9 1 9 2 Parameter Tables 9 11 ...
Page 509: ......