3-4 Cable and Connector Specifications
3
Specifications
Resistant to Bending of Robot Cables
Use Robot Cable that can withstand at least 20 million bends to the minimum bending radius (R)
given below or larger.
Note 1.
The service life data for resistant to bending is based on test data. Use it for reference only,
and provide sufficient allowance.
Note 2.
This value is the number of bends when electricity is conducted through the conductors that
will not result in cracking or damage to an extent that would affect the functionality of the
sheath. Broken shield strands may occur.
Note 3.
If a bending radius smaller than the minimum bending radius is used, it may result in
mechanical damage or ground fault damage due to insulation breakdown. If it is necessary
to use a bending radius smaller than the minimum bending radius, consult with your
OMRON representative.
Encoder Cables
@@@
: 003 to 020
■■■
: 030 to 050
Power Cables for Servomotors without Brakes
@@@
: 003 to 050
Power Cables for Servomotors with Brakes
@@@
: 003 to 050
Model
Minimum bending radius (R)
R88A-CRGA
@@@
CR
45 mm
R88A-CRGA
■■■
CR*1
50 mm
R88A-CRGB
@@@
CR
45 mm
R88A-CRGB
■■■
CR*1
50 mm
R88A-CRGC
@@@
CR
45 mm
R88A-CRGC
■■■
CR*1
50 mm
Model
Minimum bending radius (R)
R88A-CAGA
@@@
SR
45 mm
R88A-CAGB
@@@
SR
90 mm
R88A-CAGC
@@@
SR
90 mm
R88A-CAGD
@@@
SR
100 mm
Model
Minimum bending radius (R)
R88A-CAGB
@@@
BR
Power cable
90 mm
Brake Cables
45 mm
R88A-CAGC
@@@
BR
Power cable
90 mm
Brake Cables
45 mm
R88A-CAGD
@@@
BR
Power cable
100 mm
Brake Cables
45 mm
Summary of Contents for R88D-GT series
Page 20: ...18 Table of Contents ...
Page 234: ...3 133 3 8 Reactor Specifications 3 Specifications ...
Page 448: ...7 37 7 5 Manual Tuning 7 Adjustment Functions ...
Page 474: ...8 25 8 5 Periodic Maintenance 8 Troubleshooting ...
Page 475: ...Chapter 9 Appendix 9 1 Connection Examples 9 1 9 2 Parameter Tables 9 11 ...
Page 509: ......