6-13
6-4 Setting the Mode
6
Opera
tion
Alarm Codes and Meanings
Note
The following alarms are not recorded in the history.
11: Control power supply undervoltage
13: Undervoltage
36: Parameter error
37: Parameter corruption
38: Drive prohibit input error
95: Servomotor non-conformity
Software Version
• Displays the software version of the Servo Drive.
Alarm
codes
Meaning
Alarm
codes
Meaning
11
Control power supply undervoltage
45
Multi-turn counter error
12
Overvoltage
46
Encoder error 1
13
Undervoltage
47
Absolute encoder status
error
14
Overcurrent
48
Encoder phase Z error
15
Servo Drive overheat
49
Encoder PS signal error
16
Overload
58
CPU error 1
18
Regeneration overload
60
CPU error 2
21
Encoder disconnection detected
61
CPU error 3
23
Encoder communications error
62
CPU error 4
24
Deviation counter overflow
63
CPU error 5
26
Overspeed
65
Excessive analog input 2
27
Electronic gear setting error
66
Excessive analog input 3
34
Overrun limit error
73
CPU error 6
36
Parameter error
77
CPU error 7
37
Parameter corruption
81
CPU error 8
38
Drive prohibit input error
94
Encoder error 2
39
Excessive analog input 1
95
Servomotor non-conformity
40
Absolute encoder system
down error
96
CPU error 9
41
Absolute encoder counter
overflow error
97
CPU error 10
42
Absolute encoder overspeed
error
99
CPU error 11
44
One-turn counter error
ABS
ABS
ABS
ABS
Summary of Contents for R88D-GT series
Page 20: ...18 Table of Contents ...
Page 234: ...3 133 3 8 Reactor Specifications 3 Specifications ...
Page 448: ...7 37 7 5 Manual Tuning 7 Adjustment Functions ...
Page 474: ...8 25 8 5 Periodic Maintenance 8 Troubleshooting ...
Page 475: ...Chapter 9 Appendix 9 1 Connection Examples 9 1 9 2 Parameter Tables 9 11 ...
Page 509: ......