6 Troubleshooting
6 - 92
NJ-series NJ Robotics CPU Unit User’s Manual (W539)
Event name
Cannot Cancel Synchronization
Event code
5401571C hex
Meaning
The MC_SyncOut (End Synchronization) instruction cannot be executed.
Source
PLC Function Module
Source details
Instruction
Detection
timing
At instruction
execution
Error
attributes
Level
Observation
Recovery
---
Log category
System
Effects
User program
Continues
Operation
The relevant instruction will end according to specifi-
cations.
System-
defined
variables
Variable
Data type
Name
None
---
---
Cause and
correction
Assumed cause
Correction
Prevention
The MC_SyncLinearConveyor
(Start Conveyor Synchronization)
is not executed.
Execute the MC_SyncOut (End
Synchronization) instruction when
Phase
of the
TrajStatus
output
variable is 6.
Execute the MC_SyncOut (End
Synchronization) instruction only
when
Phase
of the
TrajStatus
out-
put variable from the MC_SyncLin-
earConveyor (Start Conveyor
Synchronization) instruction is 6.
The MC_SyncLinearConveyor
(Start Conveyor Synchronization)
instruction execution is in prog-
ress, but
Phase
of the
TrajStatus
output variable is not 6.
Attached
information
Attached Information 1: Error Location
Attached Information 2: Error Location Details (Rung Number). For a program section, the rung number from
the start of the section is given. For ST, the line number is given.
Attached Information 3: Names of the Instruction and Instruction Instance Where the Error Occurred. If there
is more than one possible instruction, information is given on all of them. Nothing is given if the instruction
cannot be identified.
Attached Information 4: Expansion Error Code (
ErrorIDEx
)
Precautions/
Remarks
If a program is changed after an error occurs, the attached information that is displayed may not be correct.
Summary of Contents for NJ501-4300
Page 13: ...11 CONTENTS NJ series NJ Robotics CPU Unit User s Manual W539 ...
Page 40: ...Revision History 38 NJ series NJ Robotics CPU Unit User s Manual W539 ...
Page 90: ...2 Features of NJ Robotics CPU Unit 2 40 NJ series NJ Robotics CPU Unit User s Manual W539 ...
Page 204: ...5 Vision Robot Integrated Simulation 5 6 NJ series NJ Robotics CPU Unit User s Manual W539 ...
Page 308: ...6 Troubleshooting 6 104 NJ series NJ Robotics CPU Unit User s Manual W539 ...
Page 333: ...I 1 I NJ series NJ Robotics CPU Unit User s Manual W539 Index ...
Page 335: ......