6 - 25
6 Troubleshooting
NJ-series NJ Robotics CPU Unit User’s Manual (W539)
6-2
Er
ro
r Descript
ion
6
6-
2-2 Err
or D
escriptions
Event name
Buffer Mode Selection Out of Range
Event code
542B0000 hex
Meaning
The parameter specified for the
BufferMode
input variable to a motion control instruction is out of range.
Source
Motion Control Function Module
Source details
Axis/axes group
Detection
timing
At instruction
execution
Error
attributes
Level
Minor fault
Recovery
Error reset
Log category
System
Effects
User program
Continues.
Operation
If "axis" is given for the source details, operation is
not possible for relevant axis. Relevant axis deceler-
ates to a stop if it is in motion.
If "axes group" is given for the source details, opera-
tion is not possible for relevant axes group.
Relevant axes group decelerates to a stop if it is in
motion.
If the axes group is in motion for a robot instruction, it
stops immediately.
System-
defined
variables
Variable
Data type
Name
_MC_AX[*].MFaultLvl.Active
BOOL
Axis Minor Fault Occurrence
_MC_GRP[*].MFaultLvl.Active
BOOL
Axes Group Minor Fault Occur-
rence
Cause and
correction
Assumed cause
Correction
Prevention
Instruction input parameter
exceeded the valid range of the
input variable.
Correct the parameter so that the
valid range of the input variable is
not exceeded for the instruction.
Set the input parameter to the
instruction so that the valid range
of the input variable is not
exceeded.
Attached
information
None
Precautions/
Remarks
None
Event name
Coordinate System Selection Out of Range
Event code
542C0000 hex
Meaning
The parameter specified for the
CoordSystem
input variable to a motion control instruction is out of range.
Source
Motion Control Function Module
Source details
Axes group
Detection
timing
At instruction
execution
Error
attributes
Level
Minor fault
Recovery
Error reset
Log category
System
Effects
User program
Continues.
Operation
Operation is not possible for relevant axes group.
Relevant axes group decelerates to a stop if it is in
motion.
If the axes group is in motion for a robot instruction, it
stops immediately.
System-
defined
variables
Variable
Data type
Name
_MC_GRP[*].MFaultLvl.Active
BOOL
Axes Group Minor Fault Occur-
rence
Cause and
correction
Assumed cause
Correction
Prevention
Instruction input parameter
exceeded the valid range of the
input variable.
Correct the parameter so that the
valid range of the input variable is
not exceeded for the instruction.
Set the input parameter to the
instruction so that the valid range of
the input variable is not exceeded.
Attached
information
None
Precautions/
Remarks
None
Summary of Contents for NJ501-4300
Page 13: ...11 CONTENTS NJ series NJ Robotics CPU Unit User s Manual W539 ...
Page 40: ...Revision History 38 NJ series NJ Robotics CPU Unit User s Manual W539 ...
Page 90: ...2 Features of NJ Robotics CPU Unit 2 40 NJ series NJ Robotics CPU Unit User s Manual W539 ...
Page 204: ...5 Vision Robot Integrated Simulation 5 6 NJ series NJ Robotics CPU Unit User s Manual W539 ...
Page 308: ...6 Troubleshooting 6 104 NJ series NJ Robotics CPU Unit User s Manual W539 ...
Page 333: ...I 1 I NJ series NJ Robotics CPU Unit User s Manual W539 Index ...
Page 335: ......