![background image](http://html1.mh-extra.com/html/omron/fq2-series/fq2-series_user-manual_742876475.webp)
Specifications and Dimensions
FQ2 User’s Manual
473
Appe
ndi
ce
s
12
I/O specifi-
cations
Input signals
7 signals
• Single measurement input (TRIG)
• Control command input (IN0 to IN5)
Output signals
3 signals
• Control output (BUSY)
• Overall judgement output (OR)
• Error output (ERROR)
Note: The assignments of the three output signals (OUT0 to OUT2) can be changed to the individual
judgements of the inspection items, the image input ready output (READY), or the external lighting tim-
ing output (STGOUT).
Ethernet specifi-
cations
100Base-TX/10Base-T
Communica-
tions
Ethernet TCP no-protocol,
Ethernet FINS/TCP no-protocol,
EtherNet/IP, or
PLC Link
I/O expansion
---
---
Possible by connecting FQ-SDU1
@
Sensor Data Unit.
11 inputs and 24 outputs
RS-232C
---
---
Possible by connecting FQ-SDU2
@
Sensor Data Unit.
Input specifica-
tions
Refer to Table 2.
Output specifi-
cations
Connection
method
Special connector cables
Power supply and I/O: 1 cable
(FQ-WD
@@@
)
Touch Finder and computer: 1
cable (FQ-WN
@@@
)
Special connector cables
Power supply I/O and Sensor data units: 1 cable (FQ-WD
@@@
and
FQ-WU
@@@
)
Touch Finder and computer: 1 cable (FQ-WN
@@@
)
Indications
BUSY indicator (BUSY, green), Judgement result indicator (OR, orange), error indicator (ERROR, red),
Ethernet communications indicator (ETN, orange)
Note: The assignment of the BUSY indicator can be changed to a RUN indicator (display color: green).
Ratings
Power supply
voltage
21.6 to 26.4 VDC (including ripple)
Insulation resis-
tance
Between all lead wires and case: 0.5 M
Ω
(at 250 V)
Current con-
sumption
2.4 A max.
0.3 A max.
Environ-
mental
immunity
Ambient temper-
ature range
Operating: 0 to 50
°
C
Storage:
−
25 to 65
°
C
(with no icing or condensation)
Operating: 0 to 40
°
C, Storage:
−
25 to 65
°
C
(with no icing or condensation)
Ambient humid-
ity range
Operating and storage: 35
%
to 85
%
(with no condensation)
Ambient atmo-
sphere
No corrosive gas
Vibration resis-
tance (destruc-
tion)
10 to 150 Hz, single amplitude: 0.35 mm, X/Y/Z directions
8 min each, 10 times
Shock resis-
tance (destruc-
tion)
150 m/s
2
3 times each in 6 direction (up, down, right, left, forward, and backward)
Degree of pro-
tection
IEC 60529 IP67 (Except when Polarizing Filter Attachment is mounted
or connector cap is removed.)
IEC 60529 IP40
Item
Single-function
models
Standard mod-
els
High-resolution models
Model
NPN
FQ2-
S10
@@@@
FQ2-
S20
@@@@
FQ2-
S30
@@@@
-08
FQ2-
S30
@@@@
-08M
FQ2-S30-13
FQ2-S30-
13M
PNP
FQ2-
S15
@@@@
FQ2-
S25
@@@@
FQ2-
S35
@@@@
-08
FQ2-
S35
@@@@
-08M
FQ2-S35-13
FQ2-S35-
13M
Summary of Contents for FQ2 Series
Page 1: ...User s Manual Smart Camera FQ2 Cat No Z326 E1 01A ...
Page 58: ...Setting Up Ethernet 56 FQ2 User s Manual MEMO ...
Page 90: ...Adjusting the Images That Were Taken 88 FQ2 User s Manual MEMO ...
Page 190: ...Adjusting Judgement Parameters during Operation 188 FQ2 User s Manual MEMO ...
Page 234: ...Functions Related to the System 232 FQ2 User s Manual MEMO ...
Page 404: ...Basic Troubleshooting 402 FQ2 User s Manual MEMO ...
Page 513: ...Index FQ2 User s Manual 511 Index 12 ...
Page 515: ......