System Configuration
28
FQ2 User’s Manual
Connection Compatibility
Yes: Supported, No: Not supported
*1:
This applies when an RS-232C Interface Sensor Data Unit is connected.
*2:
This applies when a Parallel Interface Sensor Data Unit is connected.
Type of connection to FQ2-S Other connection
EtherNet/IP
PLC Link on
Ethernet
TCP no-pro-
tocol commu-
nications on
Ethernet
FINS/TCP
no-protocol
communica-
tions on
Ethernet
RS-232C
*1
Parallel communications
Sensor’s
standard par-
allel commu-
nications
Parallel Inter-
face
*2
EtherNet/IP
---
No
Yes
Yes
Yes
Yes
Yes
PLC Link on Ethernet
No
---
Yes
Yes
Yes
Yes
Yes
TCP no-protocol communi-
cations on Ethernet
Yes
Yes
---
No
No
Yes
Yes
FINS/TCP no-protocol com-
munications on Ethernet
Yes
Yes
No
---
No
Yes
Yes
RS-232C
*1
Yes
Yes
No
No
---
Yes
No
Parallel
communi-
cations
Sensor’s stan-
dard parallel
communica-
tions
Yes
Yes
Yes
Yes
No
---
No
Parallel Inter-
face
*2
Yes
Yes
Yes
Yes
No
No
---
Connections Across Network Routers
You can connect to a Sensor on a different network than the Touch Finder or PC Tool through a router.
• To connect to a Sensor, directly specify the IP address of the Sensor. Automatic connection to a Sensor is not
possible.
• Use a fixed IP address for the Sensor to connect to.
Note
Summary of Contents for FQ2 Series
Page 1: ...User s Manual Smart Camera FQ2 Cat No Z326 E1 01A ...
Page 58: ...Setting Up Ethernet 56 FQ2 User s Manual MEMO ...
Page 90: ...Adjusting the Images That Were Taken 88 FQ2 User s Manual MEMO ...
Page 190: ...Adjusting Judgement Parameters during Operation 188 FQ2 User s Manual MEMO ...
Page 234: ...Functions Related to the System 232 FQ2 User s Manual MEMO ...
Page 404: ...Basic Troubleshooting 402 FQ2 User s Manual MEMO ...
Page 513: ...Index FQ2 User s Manual 511 Index 12 ...
Page 515: ......