Controlling Operation and Outputting Data with a Parallel Interface Sensor Data Unit
270
FQ2 User’s Manual
Changing the Settings of the I/O Signals
Changing the Settings of the Output Signals
●
Adjusting the Judgement Output Timing
You can change the timing of outputting the measurement result with the OR signal (after finalizing the
measurement result) according to the needs of the external device.
Adjusting the Judgement Output Timing: p. 242
●
Changing the Judgement Output ON Conditions
You change the ON condition for the OR signal to turn ON the signal when the judgement result is OK or when
it is NG.
Changing the Judgement Output ON Condition: p. 244
●
Adjusting the End Timing of the BUSY Signal
You can change the end timing of the BUSY signal.
Adjusting the Judgement Output Timing: p. 244
●
Changing the Output Polarity of the Output Signals
You can change the ON/OFF output polarity of the output signals
[In/Out]
−
[I/O setting]
−
[I/O]
−
[Output]
1
Press [Output polarity] and select the ON/OFF polarity for all output signals.
●
Setting the Output Time of the ACK Signal
You can set the output time of the normal execution completion signal for parallel commands.
[In/Out]
−
[I/O setting]
−
[I/O]
−
[Output]
−
[ACK signal ON period]
The ACK signal is not output for normal completion of continuous measurement commands.
●
Changing the Output Timing and Output Time of the STGOUT Signal
You can change the output settings of the STGOUT signal to adjust when and for how long the external lighting is lit.
Item
Parameter
Description
Output polarity
Positive (default)
Negative
You can reverse the ON/OFF conditions of the output signals.
For example, when the BUSY signal uses positive polarity, the signal is ON
while the Sensor is processing something. If you change the setting to
negative polarity, the Sensor will be ready to receive data or signals when
the BUSY signal is ON.
Applicable Output Signals
• RUN
• OR
• BUSY
• ERROR
• STGOUT
• SHTOUT
• DSA
• GATE
• D0 to D15
• ACK
Important
Summary of Contents for FQ2 Series
Page 1: ...User s Manual Smart Camera FQ2 Cat No Z326 E1 01A ...
Page 58: ...Setting Up Ethernet 56 FQ2 User s Manual MEMO ...
Page 90: ...Adjusting the Images That Were Taken 88 FQ2 User s Manual MEMO ...
Page 190: ...Adjusting Judgement Parameters during Operation 188 FQ2 User s Manual MEMO ...
Page 234: ...Functions Related to the System 232 FQ2 User s Manual MEMO ...
Page 404: ...Basic Troubleshooting 402 FQ2 User s Manual MEMO ...
Page 513: ...Index FQ2 User s Manual 511 Index 12 ...
Page 515: ......