Controlling Operation and Outputting Data with the Sensor's Standard Parallel Connection
238
FQ2 User’s Manual
Wiring
Timing Chart
1. Turn ON IN5 while IN0 to IN4 are OFF. If status is held while the BUSY signal is OFF, continuous
measurements will begin and the BUSY signal will remain ON while continuous measurements are being
performed.
2. Continuous measurements end when IN5 is turned OFF.
Settings
[In/Out]
−
[I/O setting]
−
[I/O terminals]
−
[Input]
−
[Input mode]
Press [Expanded mode].
Color
Signal
State
Description
The signals shown at the left
are used.
Refer to the following informa-
tion for signal wiring.
Wiring: p. 42
Gray
IN0
OFF
Command parameters for continu-
ous measurements
Green
IN1
OFF
Red
IN2
OFF
White
IN3
OFF
Purple
IN4
OFF
Yellow
IN5
ON
Command input for continuous
measurements
Black
OUT0 (OR)
--
Overall judgement (default assign-
ment)
Orange
OUT1 (BUSY)
--
Processing in progress (default
assignment)
OFF
O
N
OFF
O
N
OFF
O
N
OR signal
T
u
rned O
N
w
hen o
v
erall j
u
dgement is
N
G.
(OR o
u
tp
u
t: O
N
for
N
G)
O
N
w
hile meas
u
rements are
b
eing processed (depends on
BUSY o
u
tp
u
t conditions)
BUSY signal
Start contin
u
o
u
s meas
u
rements
End contin
u
o
u
s meas
u
rements
I
N
5 signal
I
N
0 to I
N
4 signals
are OFF
Allo
w
5 ms min. and then t
u
rn O
N
I
N
5.
Summary of Contents for FQ2 Series
Page 1: ...User s Manual Smart Camera FQ2 Cat No Z326 E1 01A ...
Page 58: ...Setting Up Ethernet 56 FQ2 User s Manual MEMO ...
Page 90: ...Adjusting the Images That Were Taken 88 FQ2 User s Manual MEMO ...
Page 190: ...Adjusting Judgement Parameters during Operation 188 FQ2 User s Manual MEMO ...
Page 234: ...Functions Related to the System 232 FQ2 User s Manual MEMO ...
Page 404: ...Basic Troubleshooting 402 FQ2 User s Manual MEMO ...
Page 513: ...Index FQ2 User s Manual 511 Index 12 ...
Page 515: ......