![background image](http://html1.mh-extra.com/html/omron/fq2-series/fq2-series_user-manual_742876175.webp)
Shortening the Measurement Takt Time
FQ2 User’s Manual
173
5
Testi
ng and
Sa
ving Setti
ngs
Increasing Image Input Speed
With the partial input function, it is possible to input only images that are in the region that is necessary for
measurements.
The image measurement region becomes smaller and therefore the image input time is shortened.
Consider the offset in the measurement object when you set the range.
The image in the input range will be displayed in the inspection item setting displays and measurement
displays.
[Image]
−
[Camera setup]
1
Press [
]
−
[Partial input] on the right side of the dis-
play.
2
Press [Y] and set the input range along the Y axis by
setting the Y coordinate of the partial input start
point and the Y coordinate of the partial input end
point.
3
Press [X] and set the input range along the X axis by
setting the X coordinate of the partial input start
point and the X coordinate of the partial input end
point.
4
Press [OK].
Parameter
Setting
Description
X coordinate of the partial input start
point
Range: 0 to 1,267
Default: 0
Specify the partial input range along the X
axis.
X coordinate of the partial input end
point
Range: 15 to 1,279
Default: 1,279
Y coordinate of the partial input start
point
• FQ-S
@@@@@@
Range: 0 to 472, Default: 0
• FQ-S
@@@@@@
-08
@
Range: 0 to 820, Default: 0
• FQ2-S3
@
-
@@@
Range: 0 to 1,016, Default: 0
Specify the partial input range along the Y
axis.
Y coordinate of the partial input end
point
• FQ-S
@@@@@@
Range: 7 to 479, Default: 0
• FQ-S
@@@@@@
-08
@
Range: 7 to 827, Default: 0
• FQ2-S3
@
-
@@@
Range: 7 to 1,023, Default: 0
Partial inp
u
t Y start line
Partial inp
u
t Y end line
Y coordinate of the
partial inp
u
t start point
Y coordinate of the
partial inp
u
t end point
Partial inp
u
t X
start line
X coordinate of the
partial inp
u
t start point
X coordinate of the
partial inp
u
t end point
Partial inp
u
t X
end line
Summary of Contents for FQ2 Series
Page 1: ...User s Manual Smart Camera FQ2 Cat No Z326 E1 01A ...
Page 58: ...Setting Up Ethernet 56 FQ2 User s Manual MEMO ...
Page 90: ...Adjusting the Images That Were Taken 88 FQ2 User s Manual MEMO ...
Page 190: ...Adjusting Judgement Parameters during Operation 188 FQ2 User s Manual MEMO ...
Page 234: ...Functions Related to the System 232 FQ2 User s Manual MEMO ...
Page 404: ...Basic Troubleshooting 402 FQ2 User s Manual MEMO ...
Page 513: ...Index FQ2 User s Manual 511 Index 12 ...
Page 515: ......