Controlling Operation and Outputting Data with a Parallel Interface Sensor Data Unit
FQ2 User’s Manual
275
8
Co
ntro
llin
g Operatio
n an
d Ou
tp
utti
ng Da
ta
with a Parall
el Con
nection
Output Signals
Input Signals
Signal
Function
RUN
This signal is ON while the Sensor is in Run Mode. It will be OFF in Setup Mode.
BUSY
This signal does not change while clearing errors.
However, do not clear an error while the BUSY signal is ON. The command will not be executed correctly.
OR
This signal does not change while clearing errors.
D0 to D15
These signals do not change while clearing errors.
GATE
This signal does not change while clearing errors.
ACK
When the command has been completed normally, this signal is turned ON for the time that is set for the ACK
output time.
Signal
Function
IN0
Turn ON.
IN1 to IN5
Turn OFF.
IN6
Turn ON.
IN7
This signal is the trigger for clearing an error.
Set the IN0 to IN6 signals, wait for at least 5 ms, and then turn ON the IN7 signal.