Controlling Operation and Outputting Data with the Sensor's Standard Parallel Connection
252
FQ2 User’s Manual
Clear Measurement Values
This command clears the measurement values that are stored in the Sensor. However, the OR signal and the
output signals that are assigned to OUT0 to OUT2 are not cleared.
Settings
[In/Out]
−
[I/O setting]
−
[I/O setting]
−
[Input]
−
[Input mode]
Press [Expand mode].
Wiring
Timing Chart
This function can be used in Run Mode only.
Color
Signal
State
Description
The signals shown at the left
are used.
Refer to the following
information for signal wiring.
Gray
IN0
ON
Command parameter for clearing mea-
surement values
Green
IN1
OFF
Red
IN2
ON
White
IN3
OFF
Purple
IN4
OFF
Yellow
IN5
ON
Command input for clearing measure-
ment values
Orange
OUT1 (BUSY)
--
Processing in progress (default)
1 Turn ON IN0 and IN2 and turn OFF
IN3 and IN4.
2 Turn ON the IN5 signal while the
BUSY signal is OFF to clear the
measurement values.
Note
OFF
O
N
The meas
u
rement
v
al
u
es are
cleared from the Sensor.
OFF
O
N
BUSY signal
I
N
5 signal
O
N
for 1 ms min.
Allo
w
5 ms min. and then
t
u
rn O
N
I
N
5.
I
N
0 to I
N
4 signals
Summary of Contents for FQ2 Series
Page 1: ...User s Manual Smart Camera FQ2 Cat No Z326 E1 01A ...
Page 58: ...Setting Up Ethernet 56 FQ2 User s Manual MEMO ...
Page 90: ...Adjusting the Images That Were Taken 88 FQ2 User s Manual MEMO ...
Page 190: ...Adjusting Judgement Parameters during Operation 188 FQ2 User s Manual MEMO ...
Page 234: ...Functions Related to the System 232 FQ2 User s Manual MEMO ...
Page 404: ...Basic Troubleshooting 402 FQ2 User s Manual MEMO ...
Page 513: ...Index FQ2 User s Manual 511 Index 12 ...
Page 515: ......