![background image](http://html1.mh-extra.com/html/omron/fq2-series/fq2-series_user-manual_742876137.webp)
Inspecting with the Edge Pitch Inspection Item
FQ2 User’s Manual
4
Settin
g Up In
spections
135
• If there is an edge and it cannot be detected, adjust the [Noise level] on the [Details] Tab Page and try
teaching again.
If an edge is not detected when teaching, 0 will be registered as the reference width. If the result is OKed when
there is not edge, set the judgement parameters for a reference position of 0.
Edge Not Found
The measured edge pitch will be 0. Perform the following.
• If a color was specified, make sure the color of the measurement object has not changed from the specified
color.
• Set the color again if necessary.
• If there is an edge and it cannot be detected, make sure the [Edge level] parameter on the [Details] Tab Page
is correct.
Edge level: p. 122