Controlling Operation and Outputting Data with FINS/TCP No-protocol Commands
386
FQ2 User’s Manual
Set Image Adjustment Data: 280F 00501010
This command sets parameters or measurement values from a position compensation item or filter item.
●
Format
●
Response Format
●
End Codes
●
Parameter Descriptions
MRC
(1 byte)
SRC
(1 byte)
Vision Sensor command code
(4 bytes)
Position compensation item/filter
item number (4 bytes)
External reference
number (4 bytes)
Set value (4 bytes)
28
0F
00501010
Position compensation item/filter
item number 0 to 7 (1 digit max.)
External reference
number
Setting
MRC
(1 byte)
SRC
(1 byte)
MRES
(1 byte)
SRES
(1 byte)
Vision Sensor command code
(4 bytes)
28
0F
End code
00501010
End code (hex)
Meaning
0000
Command execution ended normally.
FFFF
Command execution ended in an error.
Position compensation
item number
Specifies the number of the position compensation item or filter item to set.
External reference num-
ber
Specifies the external reference number.
12-2 External Reference Parameters: p. 430
Set value
Specifies the set value.
Summary of Contents for FQ2 Series
Page 1: ...User s Manual Smart Camera FQ2 Cat No Z326 E1 01A ...
Page 58: ...Setting Up Ethernet 56 FQ2 User s Manual MEMO ...
Page 90: ...Adjusting the Images That Were Taken 88 FQ2 User s Manual MEMO ...
Page 190: ...Adjusting Judgement Parameters during Operation 188 FQ2 User s Manual MEMO ...
Page 234: ...Functions Related to the System 232 FQ2 User s Manual MEMO ...
Page 404: ...Basic Troubleshooting 402 FQ2 User s Manual MEMO ...
Page 513: ...Index FQ2 User s Manual 511 Index 12 ...
Page 515: ......