Menu Tables
424
FQ2 User’s Manual
Sensor
set
ti
ngs
Dat
a out
put
No-pr
o
to
c
o
l d
a
ta When the com-
munications type
is RS-232C no-
protocol
Baud rate
Set the baud rate to use for RS-232C
communications.
2400, 4800, 9600, 19200, 38400, 57600,
or 115200 (default: 38400)
System
Data
length
Sets the data length.
7bit or 8bit (default: 8bit)
System
Parity
Sets the parity.
None, Odd, Even (default: None)
System
Stop bit
Sets the number of stop bits.
1bit, 2bit (default: 1bit)
System
Flow con-
trol
Sets the controls for the flow of commu-
nications with the software.
None, Xon/Xoff (default: None)
System
Delimiter
Set the delimiter to add to the end of
commands and responses.
CR, LF, or CR+LF (default:CR)
System
Interval
timeout
(text)
Timeout [s] Set the time in seconds to
generate a timeout error.
1 to 120 s, 0: Not monitored.
(default: 0 s)
System
Interval
time-
out(after
Xoff
reception)
Timeout [s] Set the time in seconds to
generate a timeout error.
1 to 120 s, 0: Not monitored.
(default: 0 s)
System
Li
nk da
ta ou
tpu
t
Communication
type
Sets the communications type to use for
EtherNet/IP or PLC Link outputs.
Invalid (default), PLC link (SYSMAC)
PLC link (MELSEC), EtherNet/IP
System
Area set-
tings(Only when
communications
type is PLC Link)
Command
Ar
ea type
Sets the area to write command data to
the Sensor.
Control inputs, command codes, and
command parameters are written to this
area.
PLC Link (SYSMAC CS/CJ/CP/One)
CIO Area (CIO) (default)
Work Area (WR)
Holding Bit Area (HR)
Auxiliary Bit Area (AR)
DM Area (DM)
EM Area (EM0 to EMC)
PLC Link (MELSEC QnU/Q/QnAS)
Data Register
File Register
Link Register
System
A
ddress
Set the first address of the command
area.
0 to 99,999 (default: 0)
System
Menu command
Description
Setting range
Data
Refer-
ence
Summary of Contents for FQ2 Series
Page 1: ...User s Manual Smart Camera FQ2 Cat No Z326 E1 01A ...
Page 58: ...Setting Up Ethernet 56 FQ2 User s Manual MEMO ...
Page 90: ...Adjusting the Images That Were Taken 88 FQ2 User s Manual MEMO ...
Page 190: ...Adjusting Judgement Parameters during Operation 188 FQ2 User s Manual MEMO ...
Page 234: ...Functions Related to the System 232 FQ2 User s Manual MEMO ...
Page 404: ...Basic Troubleshooting 402 FQ2 User s Manual MEMO ...
Page 513: ...Index FQ2 User s Manual 511 Index 12 ...
Page 515: ......