Menu Tables
FQ2 User’s Manual
423
Appe
ndi
ce
s
12
Sensor
set
ti
ngs
Startup set-
tings
Startup
mode
Sets whether the startup scene number
is set manually.
ON or OFF (Scene number when set-
tings were saved is startup scene num-
ber.)
System
Startup
scene
Set the scene number to use at startup.
Standard models: 0 to 31, Single-func-
tion models: 0 to 7, Default: 0
Password
settings
Password
ON/OFF
Enables (ON) or disables (OFF) the
password.
OFF (default) or ON
System
Enter
password
Sets a password.
15 characters max.
Adjustment mode in
Run
Sets whether to adjust measurement
contents in Run Mode.
OFF (default) or ON
---
Net
w
or
k set
ti
ngs
Ethernet
IP address set-
ting
Sets the method to use to set IP
addresses.
Auto (default), Fixed, DHCP
System
IP address
Enter the IP address of the Sensor.
(Valid only when the [IP address setting]
is set to [Fixed].)
a.b.c.d
a: 1 to 223
b: 0 to 255
c: 0 to 255
d: 2 to 254
(Default: 10.5.5.100)
System
Subnet mask
Inputs the subnet mask.
(Valid only when the [IP address setting]
is set to [Fixed].)
0.0.0.0 to 255.255.255.255
(Default: 255.255.255.0)
System
Gateway
Sets the default gateway address. (When
the [IP address setting] is set to [Fixed].)
1.0.0.1 to 223.255.255.254
(Default: 10.5.5.7)
System
Dat
a out
put
No-p
rot
o
col dat
a Communication
type
Sets the communications type to use to
output no-protocol data.
Invalid (default), No protocol (TCP), No
protocol (FINS), No protocol (RS-232C)
System
When the com-
munications type
is TCP no-proto-
col or FINS/TCP
no-protocol
Connec-
tion mode
Sets whether to communicate with the
communications devices as a server
device or a client device.
TCP server (default), TCP client
System
IP
address
Sets the IP address to which to output
no-protocol data.
* Setting is not possible if the connection
mode is set to a TCP server.
a.b.c.d
a: 1 to 223
b: 0 to 255
c: 0 to 255
d: 1 to 254
(Default:10.5.5.111)
System
Port No.
Sets the output port number.
* Setting is not possible if the connection
mode is set to a TCP server.
0 to 65535 (Default: 9600)
System
Menu command
Description
Setting range
Data
Refer-
ence
Summary of Contents for FQ2 Series
Page 1: ...User s Manual Smart Camera FQ2 Cat No Z326 E1 01A ...
Page 58: ...Setting Up Ethernet 56 FQ2 User s Manual MEMO ...
Page 90: ...Adjusting the Images That Were Taken 88 FQ2 User s Manual MEMO ...
Page 190: ...Adjusting Judgement Parameters during Operation 188 FQ2 User s Manual MEMO ...
Page 234: ...Functions Related to the System 232 FQ2 User s Manual MEMO ...
Page 404: ...Basic Troubleshooting 402 FQ2 User s Manual MEMO ...
Page 513: ...Index FQ2 User s Manual 511 Index 12 ...
Page 515: ......