4
Settin
g Up In
spections
Inspecting with the Edge Width Inspection Item
FQ2 User’s Manual
127
4-8 Inspecting with the Edge Width Inspection Item
Edge Width Inspection Item
This inspection item is used to measure dimensions. Places where the color changes greatly are called edges.
The distance between two edges is called the edge width.
Setup Procedure for Edge Width Inspection Item
Step 1
Selecting the Inspection Item
[Inspect]
−
[Inspection]
1
Press an unused inspection item number and press
[Add item.].
2
Press [Edge Width].
Registering inspection items: p. 93
Drag the arrow
at the bottom of the menu upward to display all of the inspection items.
OK
N
G
Color of edge to
b
e fo
u
nd
Meas
u
rement region
Edges are searched from
t
w
o directions and the
distance is calc
u
lated.
Sample Settings
Sample Meas
u
rement
Note