Adjusting the Judgement Parameters
FQ2 User’s Manual
175
5
Testi
ng and
Sa
ving Setti
ngs
5-3 Adjusting the Judgement Parameters
Adjusting Judgement Parameters While Looking at Measurement Results
If correct judgements are not possible, you can move directly from the Setup Mode display to the judgement
parameters display to make adjustments.
[Test] – [Continuous test] – (Either display)
Setting Up the Best Judgement Parameters Automatically
The judgement parameters of the selected inspection items can be automatically adjusted by using actual
workpieces which are considered as good and faulty products.
[Test]
−
[Continuous test]
1
Press [
]
−
[Adjust judgement] on the right of the
display.
2
Press the parameters and adjust the values of the
judgment conditions for them.
1
Move to the inspection item for which you want to au-
tomatically adjust the judgement parameters and
press [
] – [Adjust judgement] on the right side of
the display.
2
Press [
] – [Auto adjustment].
3
Display a sample image of a good object and press
[OK Teach]. Display a sample image of a bad object
and press [NG Teach].
4
Repeat these steps for at least three samples each.
5
Press [Back].
The best judgement parameters will be set automatically.
6
Press [OK].
Lo
w
er limit
Upper limit
▲
Summary of Contents for FQ2 Series
Page 1: ...User s Manual Smart Camera FQ2 Cat No Z326 E1 01A ...
Page 58: ...Setting Up Ethernet 56 FQ2 User s Manual MEMO ...
Page 90: ...Adjusting the Images That Were Taken 88 FQ2 User s Manual MEMO ...
Page 190: ...Adjusting Judgement Parameters during Operation 188 FQ2 User s Manual MEMO ...
Page 234: ...Functions Related to the System 232 FQ2 User s Manual MEMO ...
Page 404: ...Basic Troubleshooting 402 FQ2 User s Manual MEMO ...
Page 513: ...Index FQ2 User s Manual 511 Index 12 ...
Page 515: ......